Description

Interlock Limits for Ablenksmagnet (Test n. 2 in old caRPS_Tests)

Parameters

ilkInExpectedValS [hex] Interlock Input expected value for small values of magnet
magnetCh Magnet epics channel
ilkInCh Interlock Input epics channel
ilkInExpectedValIni [hex] Interlock Input expected initial value
ilkOutExpectedValL [hex] Interlock Output expected value for large values of magnet
magnetEndVal [int] magnet final value for scan sequence
ilkOutCh Interlock Output epics channel
ilkOutExpectedValIni [hex] Interlock Output expected initial value
ilkOutExpectedValS [hex] Interlock Output expected value for small values of magnet
magnetInitVal [int] magnet initial value for scan sequence
setGetDelay [s] delay between set and get

Contact

Marco Boccioli
Tel. 3078